Investigation of the effect of different surface treatments for preventing detachment of polyetheretherketone and titanium attachment matrix housings in overdentures: An in vitro study

dc.contributor.authorYıldız, Pınar
dc.contributor.authorUnlu, Damla Gunes
dc.date.accessioned2025-02-24T17:18:28Z
dc.date.available2025-02-24T17:18:28Z
dc.date.issued2023
dc.departmentFakülteler, Diş Hekimliği Fakültesi, Restoratif Diş Tedavisi Ana Bilim Dalı
dc.description.abstractAim:The attachment matrix housing (AMH) of implant overdentures is not chemically bonded with acrylic resins. Therefore, AMH may lose due to insertion and removal forces. This study aims to investigate the effects of different surface treatments to reduce the detachment of AMH and to compare the adhesion of the AMH used in implant-supported overdentures made of different materials with the reline acrylic resin.Materials and Methods:Titanium and polyetheretherketone (PEEK) AMHs were separated into four surface treatment groups; no treatment, airborne-particle abrasion (APA) applied, universal bond (UB) applicated, APA, and UB applicated. Eight millimeters in diameter and ten millimeters tall straws were used to restrain the reline acrylic resin prepared according to the manufacturer's instructions and the resin was injected onto the surface-treated AMH. After the polymerization was completed, the universal testing machine performed the tensile bond strength (TBS) test with a fishing line passed through the acrylic resins.Statistical Analysis Used:TBS data were analyzed with two and one-way ANOVA and Tukey HSD post hoc tests (alpha =0.05).Results:According to the two-way ANOVA results, titanium AMHs (103.78 +/- 45.98 N) showed higher TBS than PEEK AMHs (67.81 +/- 28.61 N). UB applicated titanium groups showed significantly increased TBS values.Conclusions:Using titanium AMHs may be a better choice in situations where clinical aesthetic expectations are unimportant for adhesion to reline acrylic resins.The UB resin significantly increased the bonding of the titanium AMHs with reline resins. The application of UB resin to titanium housings can be easily applied in a clinical situation and can reduce the detachment of the titanium AMHs.Conclusions:Using titanium AMHs may be a better choice in situations where clinical aesthetic expectations are unimportant for adhesion to reline acrylic resins.The UB resin significantly increased the bonding of the titanium AMHs with reline resins. The application of UB resin to titanium housings can be easily applied in a clinical situation and can reduce the detachment of the titanium AMHs.
dc.description.sponsorshipNuh Naci Yazg an University [2019-SA.DH-BP-2]
dc.description.sponsorshipThis study was supported by Nuh Naci Yazg an University, Scientific Research Projects Unit 2019-SA.DH-BP-2.
dc.identifier.doi10.4103/jips.jips_497_22
dc.identifier.endpage149
dc.identifier.issn0972-4052
dc.identifier.issn1998-4057
dc.identifier.issue2
dc.identifier.scopus2-s2.0-85153905217
dc.identifier.scopusqualityQ2
dc.identifier.startpage142
dc.identifier.urihttps://doi.org/10.4103/jips.jips_497_22
dc.identifier.urihttps://hdl.handle.net/20.500.14440/683
dc.identifier.volume23
dc.identifier.wosWOS:001379867000013
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherWolters Kluwer Medknow Publications
dc.relation.ispartofJournal of Indian Prosthodontic Society
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_WOS_20250201
dc.subjectAirborne-particle abrasion
dc.subjectoverdenture
dc.subjectpolyetheretherketone
dc.subjecttitanium
dc.subjectuniversal bond resin
dc.titleInvestigation of the effect of different surface treatments for preventing detachment of polyetheretherketone and titanium attachment matrix housings in overdentures: An in vitro study
dc.typeArticle

Dosyalar