Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Usumez, Aslihan" seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    Effect of Photobiomodulation Therapy on Peri-Implant Bone Healing in Extra-Short Implants in a Rabbit Model: A Pilot Study
    (Mary Ann Liebert, Inc, 2022) Kuzu, Turan Emre; Ozturk, Kuebra; Gurgan, Cem A.; Usumez, Aslihan; Yay, Arzu; Goktepe, Ozge
    Objective: To evaluate the effects of photobiomodulation therapy (PBMT) at distinct energy levels on peri-implant bone healing in extra-short implants in a experimental rabbit model.Background: The effect of PBMT on peri-implant bone healing in short implants remains unclear. This explored the effect of PBMT on extra-short implants in terms of bone-implant contact (BIC) length and rate, and implant stability quotient (ISQ).Methods: Fifteen white New Zealand rabbits were randomly divided into five groups. In all groups, extra-short implants (3.5 x 4 mm; Nucleoss T6, Izmir/Turkey) were placed in both tibias of the rabbits. PBMT was performed in four groups (group 1, 5 J/cm(2); group 2, 10 J/cm(2); group 3, 20 J/cm(2); and group 4, 25 J/cm(2)); no PBMT was performed in the control group. On the 30th day, the rabbits were sacrificed and peri-implant tissue samples were obtained to determine the BIC length and BIC rate. Implant stability levels were measured by resonance frequency analysis using the Osstell penguin device and were determined as ISQ values on the 1st and 30th days of the study.Results: PBMT significantly increased the BIC length and BIC rate in groups 3 and 4 (p < 0.001). For the ISQ values, there were significant differences between the 1st and 30th day (p < 0.001). On the 30th day, the ISQ values were significantly higher in groups 3 and 4 compared with the remaining groups (p < 0.001).Conclusions: In this study, PBMT improved peri-implant bone healing through increase in BIC length, BIC rate, and ISQ parameter values in extra-short implants.
  • [ X ]
    Öğe
    Removal of lithium disilicate veneers with Er,Cr:YSGGL laser: now? Or after ageing?
    (Springer London Ltd, 2022) Yıldız, Pınar; Unlu, Damla Gunes; Cevlik, Esra Talay; Usumez, Aslihan
    This study was purposed to assess the impact of ageing and resin cements polymerized with different modes on the removal time of lithium disilicate (LiSi) ceramics using Er,Cr:YSGG laser. Ninety LiSi slabs (6 x 6 x 1 mm) were cemented to freshly extracted bovine teeth using cements polymerized with different modes (light-curing (LC), dual-curing (DC), self-curing (SC)). The specimens were divided into subgroups according to ageing conditions (no thermal cycling, 5000 or 30,000 thermal cycling). After that, Er,Cr:YSGG laser was applied until LiSi slabs were debonded; the removal time was recorded. Vickers microhardness test, SEM and EDS analyses were performed for specimens with the longest exposure time to laser application in the groups. One uncemented sample was also used as a control. Data were analyzed with two-way ANOVA and Tukey post hoc test. Ageing and cement polymerization mode significantly affected the removal time of LiSi specimens. The removal time for the self-curing resin cement group (22.67 +/- 12.68 s) was significantly longer than for cements polymerized with other methods (LC = 10.833 +/- 7.28 s, DC = 12.0 +/- 7.96 s). Removal time was significantly reduced after ageing in all polymerization modes; however, there were no significant differences between 5000 (11.83 +/- 7.52 s) and 30,000 (11.83 +/- 7.26 s) thermal cycling groups. Self-curing resin cements had prolonged the laser-aided removal time for LiSi ceramics. It can be concluded that Er,Cr:YSGG laser-aided removal of LiSi veneers after clinical use can be done more faster than its immediate removal.

| Nuh Naci Yazgan Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Ertuğrul Gazi Mahallesi, Nuh Naci Yazgan Yerleşkesi, Kocasinan, Kayseri, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim